The thyristor shown in the circuit below is triggered at a phase angle of \( \pi / 5 \) in every positive half cycle of the a

 

The thyristor shown in the circuit below is triggered at a phase angle of \( \pi / 5 \) in every positive half cycle of the applied voltage \( \mathrm{V}_{\mathrm{s}}=240 \mathrm{Sin} \omega \mathrm{t} \). Draw the voltage waveforms across the load and the Thyristor indicating timings of ON and OFF of the Thyristor. Calculate the average voltage, RMS voltage across the load (Lamp), and then determine: (a) the rectification efficiency (b) the form factor \( \mathrm{FF} \) (c) the ripple factor \( \mathrm{RF} \) (d) the peak inverse voltage PIV of thyristor


We have an Answer from Expert

View Expert Answer

Expert Answer


The voltage wave