(Solved): A communication receiver is connected to an antenna by a 300ohm transmission line that is 125m lo ...
A communication receiver is connected to an antenna by a 300ohm transmission line that is 125m long. The line has a loss of 3dB per 100m. The noise figure for the receiver is 16dB. Calculate: a) The overall noise figure. b) The overall noise figure if a preamplifier with a gain of 20dB and a noise figure of 3dB is connected to the receiver. [7] c) The overall noise figure if the preamplifier is connected between the antenna and the transmission line instead. [7]