Home / Expert Answers / Civil Engineering / 5-an-a-36-steel-column-has-a-length-of-7-mathrm-m-it-is-pinned-at-both-ends-in-front-vi-pa736

(Solved): 5. An A-36 steel column has a length of \( 7 \mathrm{~m} \). it is pinned at both ends in front vi ...



5. An A-36 steel column has a length of \( 7 \mathrm{~m} \). it is pinned at both ends in front view and is fixed at both end

5. An A-36 steel column has a length of \( 7 \mathrm{~m} \). it is pinned at both ends in front view and is fixed at both ends in side view. If the cross sectional area has the dimensions shown, determine the critical load. \( \mathrm{E}=200 \mathrm{GPa} . \quad \) (15points)


We have an Answer from Expert

View Expert Answer

Expert Answer


For this type of column we have to treat the both column separately, STEP 1: Consider the Front view of the column where both ends were pinned, yPPL G